Interactive Engineering Tool

Almen Intensity Calculator

Calculate saturation points, analyze arc height data, and determine optimal peening intensity per SAE J442 standards.

Saturation Curve Analysis

Enter at least 2 exposure times in ascending order

Enter arc heights corresponding to each exposure time

Example Dataset

Exposure Times: 2, 4, 6, 8, 10 minutes

Arc Heights: 0.008, 0.012, 0.014, 0.015, 0.0155 "A

Copy these values into the calculator to see how saturation analysis works.

Saturation Criterion

Saturation: h(2T)/h(T) ≤ 1.10

When doubling the exposure time results in ≤10% increase in arc height, the process has reached saturation.

Quick Reference

  • Minimum data points:4 strips
  • Time interval ratio:2× (doubling)
  • Measurement accuracy:±0.0005"A
  • Standard:SAE J442